Vue de la page 0
Agilent 34980A
Multifunction Switch/Measure Unit
Data Sheet
8-slot mainframe with 19 mix-and-
match plug-in modules so you can
create your own custom configura-
tion
High-performance switching:
Up to 560 2-wire multiplexer chan-
nels or 1024 matrix cross-points in
one mainframe
Optional built-in 6
1
2 -digit DMM lets
you make 11 measurements with up
to 2000 readings/sec
Easy to integrate: Built-in Ethernet,
USB 2.0, and GPIB connectivity,
standard connectors and software
drivers for most common program-
ming environments
CONFIGURE, CONNECT, GO
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Agilent 34980A

Agilent 34980A Multifunction Switch/Measure Unit Data Sheet• 8-slot mainframe with 19 mix-and-match plug-in modules so you cancreate your own custom c

Page 2 - Optimized for test systems

34980A matrix switch modulesThe 34980A matrix modules are fullcross-point matrices that allow you to connect any row to any column.This is a convenien

Page 3 - Measurements you can trust

11Table 3. Matrix selection table—specifications and characteristics*34931A 34932A 34933AChannels/configurations dual 4x8 dual 4x16 dual 4x88x8 8x16 8

Page 4 - Standard interfaces take the

34980A general-purpose switchmodules The 34980A general-purpose switchescan be used to route signals or to control other system devices. Theseswitches

Page 5

34980A RF and microwaveswitch modulesThe 34980A offers a variety of RFand microwave switch modules—RF multiplexers, SPDT switchingfrom DC to 20 GHz, o

Page 6 - 4 current channels

14Table 5. RF and microwave selection table—specifications and characteristics*DC to 3 GHz DC to 20 GHz [3]34941A 34942A 34946A 34947AChannels quad 1x

Page 7 - 34980A multiplexer switch

34945A/34945EXT microwaveswitch/attenuator driverThis module allows you to controlswitches attenuators, and otherdevices external to the 34980A. The 3

Page 8

34950A 64-channel digital I/O with memory and counter This module can be used to simulateor detect digital patterns. It has eight8-bit digital I/O cha

Page 9

34951A 4-channel isolated D/A converter with wave-form memory This module has four independent,isolated channels that output DC voltage up to ± 16 V o

Page 10 - 34980A matrix switch modules

34952A multifunction modulewith 32-bit DIO, 2-channel D/Aand totalizer The multifunction module offers theflexibility you need for system control.The

Page 11

34959A breadboard module Use this module to create your owncustom designs inside the 34980Amainframe. You can control your custom circuits with access

Page 12 - 34980A general-purpose switch

If you use automated test equipmentfor design validation or manufactur-ing, you now have a cost-effective alternative to PXI and VXI test-systemplatfo

Page 13 - 201 202COM

2034980A system specifications and characteristics(for complete specifications, see the 34980A Users Guide)DMM accuracy ± (% of reading + % of range)I

Page 14 - 10 uV 10 uV N/A N/A

21Temperature measurement accuracy ± (% of reading + % of range)Temperature Type 1-year accuracy [1]24 hour Extended range[1]1-year accuracy Temp Coef

Page 15 - 34945A/34945EXT microwave

22Measurement characteristics with optional internal DMMDC voltageMeasurement method Continuously integrating multi-slope III A-D converterA-D linear

Page 16 - 34980A system control modules

23System specificationsScanning inputsAnalog: 34921A, 34922A, 34923A, 34924A, and 34925A multiplexer channelsDigital: 34950A/52A digital in and tota

Page 17 - 34951A 4-channel isolated

24Ordering informationDescription Optional Interconnect Commentsterminal block cables / connector kits34980A Multifunction switch/measure mainframe— N

Page 18 - 34952A multifunction module

25AccessoriesY1130A Rackmount kit for 34980A, forward or reverse mountCables/connector KitsY1135A 1.5m 50pin Dsub, M/F twisted pair with outer shield

Page 19 - 34959A breadboard module

Agilent Technologies’ Test and MeasurementSupport, Services, and AssistanceAgilent Technologies aims to maximize the valueyou receive, while minimizin

Page 20

Make system connections easily and quickly with simple, reliable connection options:• Built-in Ethernet, USB 2.0, andGPIB connectivity • Standard IVI

Page 21

4Modules provide flexible system stimulus and controlSystem control—with analog outputs,open-collector digital outputs, clockgeneration, and isolated

Page 22 - Selectable on 100 Ω, 1k Ω

Intuitive front panel with self-guiding menusSet up scan listsSee results on bright, multiline displayScan multiple channels, close specified channel

Page 23 - System specifications

6The 34980A mainframe holds up to eight plug-in modules.Mix and match them to create a custom system to meetyour switching and system control needs. Y

Page 24 - Ordering information

734980A multiplexer switchmodulesThe 34980A multiplexer modules can be used to connect one of manydifferent points to a single point. You can connect

Page 25 - Related Agilent literature

Multiple multiplexers can connect to the built-in analog buses, allowingyou to scan up to 560 2-wire channelsor 640 1-wire channels in a singlemainfra

Page 26 - Agilent Email Updates

9Table 2. Multiplexer selection table—specifications and characteristics*34921A 34922A 34923A 34924A 34925AChannels/configurations 40 2-wire 70 2-wir