TEST & MEASUREMENT PRODUCT GROUP
600 East Greenwich Avenue • West Warwick, RI 02893
Phone: 401-828-4000 • Fax: 401-822-2430
toll-free phone: 877-867-9783
Dash 8Xe and AstroDAQ Xe Module Specifications
(Updated December, 2005)
NDV1 Differential, non-isolated input module
Connector Guarded banana jacks (red/black)
Isolation No
Bandwidth (5V Attenuator) 28 KHz (-3db)
Bandwidth (40V Attenuator) 34 KHz (-3db)
Input Differential, DC coupled
Off Ground Measurements Yes
Zero Suppression Yes, digital.
Measurement Ranges +/- 5 V (5 VFS or 10 VFS w/ zero offset)
+/- 40 V (40 VFS or 80 VFS w/ zero offset)
Max Rated Input +/- 40 V
Max Transient Input +/- 40 V
A/D 14 bit SAR
Anti-Aliasing Filter 4 pole Bessel
Accuracy (25°C) 0.25 % of attenuator (12.5 mV and 100 mV)
Cold Start Drift Less than 0.5% of attenuator
Overshoot Less than 1% of attenuator
Intrinsic Noise (pk-pk) < 0.1 % of attenuator
Min Input Impedance 425 K
CMR at 60 Hz Better than -60 dB
Channels Per Module 1
Frequency Counter No
Module Part Number 32750-000
Specifications subject to change without notice
Vue de la page 0
1 2 3 4 5 6 7 8 9

Résumé du contenu

Page 1

1. TEST & MEASUREMENT PRODUCT GROUP 600 East Greenwich Avenue • West Warwick, RI 02893 Phone: 401-828-4000 • Fax: 401-822-2430 toll-free ph

Page 2

2. IHV1 Isolated high voltage module Connector Guarded banana jacks (red/black) Isolation 250 VRMS or DC, Cat II. (iso-common to chassis

Page 3

3. IBR1 Isolated differential/ bridge amplifier with DC excitation Connector 5 wire screw terminal Isolation 250 VRMS or DC, Cat II (iso-

Page 4

4. IHV2 Isolated very high voltage module Connector Guarded Banana Jacks Isolation 600 VRMS or DC Cat II (either input to chassis and

Page 5

5. IRTD Isolated RTD amplifier for Pt 100 Resistance Temperature Detectors Connector 4 wire screw terminal Isolation Yes Bandwidth 2.5 H

Page 6

6. ITCU Universal thermocouple amplifier Connector Type U miniature thermocouple Isolation 250 VRMS or DC, Cat II. Bandwidth 5 Hz upd

Page 7

7. LIVM Low impedance voltage module with DC current excitation Channels Per Module 1 A/D 16 bit SAR Anti-Aliasing Filter 4 pole Bessel

Page 8

8. IDCV Isolated high accuracy, wide dynamic range DC voltmeter Connector Guarded banana jacks (red/black) Isolation 250 VRMS or DC, Cat

Page 9

9. IHV3 High voltage module Connector Guarded banana jacks (red/black) Isolation 250 VRMS or DC, Cat II. (iso-common to chassis and other