Surge Generator for MIL-STD 1275
This generator PG1275 is specially designed for the test of the susceptibility to surges and
spikes of military 28 Vdc electric circuits. The equipment allows performing the following tests
according to MIL-STD 1275D of: imported and exported spikes, imported and exported surges.
The surge voltages are supported up to 125 V and the spike charging voltage up to +/-500 V.
The maximum permanent current of the 5 µH internal coil is 400 A dc. The pulse generator can
be ordered with all the accessories in order to build the full test set-up basically consisting of
batteries and an oscilloscope. The generator can be fully controlled by a computer through a
RS232 or an USB interface.
SPECIFICATIONS
Type PG1275
Standard
MIL-STD-1275D
Transients supported
imported and exported spikes
imported and exported surges
Test equipment operating voltage
28 Vdc
Test equipment operating current
400 A
Inductor
5 µH 400 A
Output connectors
ITT IP67 400 A
Remote control
RS232 and USB
Operating temperature
0 – 40
o
C
Power supply
90 - 264 V
ac
/ 50 - 60 Hz / 100 VA
Dimensions
53 x 53 x 53 cm (W x H x L)
Weight
50 kg