Atec Haefely-PLINE1610 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Atec Haefely-PLINE1610. Atec Haefely-PLINE1610 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
PLINE 1610
Tester for Voltage Dips, Interruptions and Variations
Voltage Dips and short Interruptions are
caused by faults in the network or sudden large load
changes. Voltage variations are caused by continuously
varying loads connected to the network.
PLINE 1610 contains all the features expected from a
top quality generator in a compact solution.
PLINE 1610 has two integrated motorized
variable transformers (variacs). One transformer is
used to adjust the nominal voltage, for example 230V
or 120V, independently from the actual mains voltage.
This is essential to ensure reproducible test results.
This variac is also used for performing the voltage
variations.
A second variac provides the Dips voltage level, for
example 40% or 80% of the nominal voltage.
In opposition to most other products, no additional
external transformers, variacs, power sources, wiring
etc. are required. Therefore, this totally integrated
solution is easy to use and guarantees full compliance
to the IEC/EN 61000-4-11 standard.
All test parameters of the PLINE 1610 can be selected
in a surpassing wide range, exceeding the basic
standard requirements. This also ensures that special
test requirements can be fulfilled without any
problems.
Up to 18 tests can be stored in the unit, and these
tests can be linked in any sequence to program. Up to
18 programs can be defined and stored. Along with
the transition function for all basic parameters,
extremely complex test routines can also be
defined and executed very comfortably.
Using the integrated BNC-monitor outputs, actual
voltage and current can be displayed on a CRO
without any additional equipment required.
PLINE 1610 contains a triple protection against
overloads and therefore it is strengthened against
overcurrents or short circuits that may be caused by
the EUT during testing.
Features
Compact and complete test system
Predefined Tests and Programs
Testing according to IEC/EN 61000-4-11
Selectable current limit to protect EUT
Automatic Test Report generation
Flexible to meet individual needs
Remote control via RS-232
Centronics printer interface
Fully automatic testing of complex test routines
Benefits
International application - Specifically designed
to meet and exceed the requirements of IEC, EN and
other standards.
Turnkey Test System - PLINE 1610 is complete.
No additional boxes, cabling, etc. required as with
most other products.
Easy to use - Simple test setup, no risk of operating
errors.
Fully Compliant - PLINE 1610 Dips and Interrupts
are fully compliant to the standard.
Totally reproducible test results - This ensures
that the EUT is neither overtested nor undertested.
Over- or undertesting a product may result in
extensive, unnecessary costs.
Report Generation - Fully automated test report
generation.
Applications
Dips and Interrupts according to
IEC/EN 61000-4-11 Edition 1 & Edition 2
IEC/EN 61000-6-1
IEC/EN 61000-6-2
Many more international product standards
Product development
Vue de la page 0
1 2

Résumé du contenu

Page 1 - PLINE 1610

PLINE 1610 Tester for Voltage Dips, Interruptions and Variations  Voltage Dips and short Interruptions are caused by faults in the network or sud

Page 2 - Options and Accessories

Headquarters Haefely Test AG Lehenmattstrasse 353 CH-4052, Basel Switzerland  + 41 61 373 41 11  + 41 61 373 45 99  [email protected] Lo

Commentaires sur ces manuels

Pas de commentaire