F6150
Over 10,000 Doble
®
protection test
instruments are currently used by
test engineers around the world,
to ensure the reliability of electric
power systems.
TECHNICAL SPECIFICATIONS
Total Sources
The F6150 can provide up to twelve simultaneous user configurable AC/DC sources
including: six convertible sources and six current sources.
Convertible Sources
Each 150 VA Convertible Source can be used as a voltage source or optionally as a
high-power, low range current source. The F6150 has up to six Convertible Sources.
Source Configurations
Output Power
Continuous Transient for 1.5 Seconds Number of Sources
75 VA 97.5 VA 6
150 VA 195 VA 3
300 VA 390 VA 2x150 VA or 1x150 VA+2x75 VA
450 VA 585 VA 1
Each 150 VA convertible source can be split into two 75 VA sources.
Two 150 VA convertible sources can be combined in parallel into one 300 VA current source.
Three 150 VA convertible sources can be combined in parallel into one 450 VA current source.
Ranges and Resolution
75 VA Source F6150 Ranges (Resolution)
AC Voltage 75, 150 V rms (0.01V)
DC Voltage 106, 212 V dc (0.01V)
AC Current
Transient 0.75, 1.5 A rms (0.0001
A)
Continuous 0.5, 1.0 A rms
(0.0001 A)
DC Current
Transient 0.53, 1.06 A dc (0.0001
A)
Continuous 0.354, 0.707 A dc
(0.0001 A)
150 VA Source F6150 Ranges (Resolution)
AC Voltage 75, 150, 300 V rms
(0.01 V)
DC Voltage 106, 212 V (0.01 V), 300
VDC (0.1 V)
AC Current
Transient 0.75, 1.5, 3.0 A rms
(0.0001 A)
Continuous 0.5, 1.0, 2.0 A rms
(0.0001 A)
DC Current
Transient 0.53, 1.06 (0.0001 A),
2.12 A dc (0.001 A)
Continuous 0.354, 0.707 (0.0001 A),
1.41 A dc (0.001 A)
300 VA Source F6150 Ranges (Resolution)
AC Current
Transient 1.5, 3.0, 6.0 A rms
(0.001 A)
Continuous 1.0, 2.0, 4.0 A rms
(0.001 A)
DC Current
Transient 1.06 A (.0.0001 A), 2.12,
4.24 A dc (0.001 A)
Continuous 0.707 A (0.0001 A), 1.41
A, 2.83 A dc (0.001 A)
450 VA Source F6150 Ranges (Resolution)
AC Current
Transient 2.25, 4.5, 9.0 A rms
(0.001 A)
Continuous 1.5, 3.0, 6.0 A rms
(0.001 A)
DC Current
Transient 1.59 (0.0001 A), 3.18,
6.36 A dc (0.001 A)
Continuous 1.06, 2.12, 4.24 A dc
(0.001 A)
®
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Convertible Sources

F6150Over 10,000 Doble® protection test instruments are currently used by test engineers around the world, to ensure the reliability of electric power

Page 2 - Current Sources

AustraliastrstrstriaAChinaChCIndiadNorwayyUKUUnited StatesSSStaCurrent SourcesThe F6150 has up to twelve current sources available including: six curr

Page 3 - F6150 Technical Specifications

AustraliastrstrstriaAChinaChCIndiadNorwayyUKUUnited StatesSSStaAC Amplitude Accuracy at 50/60 Hz Voltage and Current SourcesFrom 20° to 30° C: <0.

Page 4 - General Specifications

General SpecificationsInterfacesEthernet or USB control to PCLine Power Supply105–132 V or 210–264 V, 47–63 HzEMC EmissionsFCC 47 CFR Part 15 Class A (