160 School House Road Souderton, PA 18964-9990 • 215-723-8181 • www.ar-worldwide.com Page 1 of 2
Model FM7004 Field Monitor
M1 through M4
0.4-1000 V/m
12.0 mA/m-17 A/m Sensitivity
The AR RF/Microwave Instrumentation Model FM7004 is a versatile electric and magnetic field monitoring system which
performs all measurement display and control functions for field related testing. The FM7004 accepts inputs from up to 4
isotropic Field Probes which are all sold separately to match the test application.
The FM7004 field monitor provides four digital interfaces
(IEEE-488, USB, RS-232, and Ethernet) and a highly
readable, user configurable, graphic Liquid Crystal
Display. The monitor is menu driven and can be
controlled from the front panel or remotely through any of
the interfaces. The FM7004 displays up to four probe
readings simultaneously, in any combination of the "E"
field or "H" field 7000 series probes. Readings from each
axis, plus the composite reading, are displayed
simultaneously. The FM7004 recognizes each attached 7000 series probe (FP, FH, FL) and automatically displays the
proper decimal places and units. Any faults that occur will be logged and the unit is programmed to be self correcting
when possible. As a software driven instrument, field monitor software upgrades can be made through the USB port.
The isotropic field probes, have an integral optical transceiver which communicates with the field monitor through a twin
fiber optic cable. The operator can select minimum, maximum or average reading from any or all selected probes thus
enjoying complete flexibility in choice of signal input. Peak hold capability has also been incorporated with local or remote
controlled start and stop.
The FM7004 has the ability to correct probe readings over frequency using a set of correction factors stored in its internal
memory. The FM7004 allows for up to six tables of field probe correction factors to be stored. One table of correction
factors can contain up to 30 different frequency points. The tables are loaded on the FM7004 using the USB port and the
Table Loader program.
DISPLAY MODES
Single Probe X,Y,Z Display Multi-probe X,Y,Z Display
Min/Max/Average Display Min/Max Hold Display
Vue de la page 0
1 2

Résumé du contenu

Page 1

051608 160 School House Road Souderton, PA 18964-9990 • 215-723-8181 • www.ar-worldwide.com Page 1 of 2 Model FM7004 Field Monitor M1 through M4 0.4

Page 2

Page 2 of 2 SPECIFICATIONS Sensitivity..................0.4–1000 V/m (probe dependent) 12.0 mA/