Vue de la page 0
Agilent U1610A/U1620A Handheld
Digital Oscilloscope
Data Sheet
Retool your expectations in the world’s first VGA
display handheld oscilloscope with two isolated
channels
The U1610A/U1620A is the world’s first handheld oscilloscope with a VGA
display. This 100/200 MHz handheld oscilloscope offers a floating measurement
capability with two CAT III 600 V isolated channels. With up to 2 GSa/s sam-
pling rate and 2 Mpts memory depth, it captures more waveforms from signals
such as pulse width modulated circuit, in rush, transient, and motor start up
sequences. The benchtop-like display and dual window zoom allow you to easily
identify problem areas and zoom in for more detailed analysis. Now, you can
view signals in detail and detect glitches easily.
Features
100/200 MHz bandwidth with
two isolated channels
5.7-inch VGA TFT LCD display
with 3 selectable viewing
modes (indoor, outdoor and
night vision)
2 Mpts memory depth and
2 GSa/s sampling rate allows
detailed analysis of captured
glitches
10,000-count resolution on
DMM display
• Channel-to-channel isolation
with CAT III 600 V safety
ratings
Data logging capability to PC
10 selectable languages on
the User Interface (UI) system
Night vision viewing modeIndoor viewing mode
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Digital Oscilloscope

Agilent U1610A/U1620A Handheld Digital Oscilloscope Data SheetRetool your expectations in the world’s first VGA display handheld oscilloscope with two

Page 2 - Outdoor mode

10General specifications Power supplyPower adapter Line voltage range: 50/60 Hz, 100 to 240 VAC, 1.6 AOutput voltage: 15 VDC, 4 AInstallation Category

Page 3 - Front panel description

11Recommended accessoriesItem DescriptionU1560AScope probe x1 CAT III 300 V • Include ground alligator clip and hook clip, rated CAT III 300 VU1562AS

Page 4 - Specifications

www.agilent.comwww.agilent.com/find/handheldscopewww.agilent.com/find/U1600www.lxistandard.orgLAN eXtensions for Instruments puts the power of Etherne

Page 5 - Specifications (continued)

2Figure 1. Indoor mode for clear distinct readingsFigure 2. Outdoor mode that is sunlight viewableFigure 3. Night vision mode for performing tasks in

Page 6

3Front panel descriptionFigure 4. The U1620A as shownDirectional keysMeter terminalsMeasurement softkeysTo make quick measurements and place cursors o

Page 7 - Channel isolation

4SpecificationsU1610A U1620ASpecificationVertical systemBandwidth (-3 dB) 1100 MHz 200 MHzDC vertical gain accuracy 1± 4% of full scaleFull scale is e

Page 8 - Test current

5Specifications (continued)U1610A U1620ACharacteristic (continued)Horizontal systemRange 5 ns/div to 50 s/div 2 ns/div to 50 s/divResolution 100 ps fo

Page 9 - Data logger specifications

6U1610A U1620ACharacteristic (continued)Display systemDisplay 5.7" TFT LCD VGA Color (outdoor readable)Resolution VGA (screen area): 640 vertical

Page 10 - General specifications

7Maximum input voltages and channel isolationFigure 5. Maximum safety voltage for scope reference to earthFigure 6. Maximum input voltageU1610A and U1

Page 11 - Ordering information

8Digital multimeter specifications• Accuracy is given as ± (% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity

Page 12 - Certified

9Digital multimeter specifications (continued)Maximum reading10,000 counts with automatic polarity indicationVoltage 1CAT II 1000 V or CAT III 600 VFu